当前位置:网站首页>What is the difference between the four common resistors?
What is the difference between the four common resistors?
2022-08-09 16:03:00 【Only 123 mall】
Today, Xiaobian will introduce the difference between the following four kinds of resistance:
1. Insulation resistance
Apply a DC voltage to the medium.After a certain period of polarization, the corresponding leakage current flowing through the dielectric is called insulation resistance.Insulation resistance is the most basic insulation index for electrical equipment and electrical lines.The insulation resistance of low-voltage electrical installations, motors, power distribution equipment and distribution lines shall not be less than 0.5 MΩ (the insulation resistance of operating equipment and wiring shall not be less than 1 MΩ/kv).The insulation resistance of low-voltage electrical appliances and their connecting cables and secondary circuits is generally not less than 1MΩ; in a relatively humid environment, it should not be lower than 0.5MΩ; the insulation resistance of small circuit and small busbars should not be less than 10MΩ.The insulation resistance of Class I hand-held power tools shall not be less than 2MΩ.

2. Grounding resistance
Ground resistance is the resistance encountered when current flows from a grounded device into the ground and then through the ground to another grounded body or travels to a distance.The unit of measurement is Ω.The size of the grounding resistance can reflect the degree of contact between the electrical device and the earth and the size of the grounding grid.
Ground resistance measurement methods include two-wire method, three-wire method, four-wire method, single-clamp method and double-clamp method.Each of these five methods has its own characteristics.In the actual measurement, try to choose the correct measurement method and measurement instrument to ensure the accuracy of the results.

3. DC group
This type of resistance is mainly used for DC resistance testing of inductive loads such as transformers, motors, CT/PT, etc. The measurement unit is mΩ.It can reflect the welding quality of the winding, the short circuit between turns of the winding, the disconnection of the winding or the disconnection of the lead wire, the poor contact of the tap changer and the wire and so on.In fact, it is also an effective means to judge whether the DC resistance of each phase winding is balanced and whether the voltage regulator switch is correct.
DC resistance measurement methods include: current-voltage method, DC bridge method, and three-phase winding simultaneous compression method. Now DC resistance testers generally use DC bridge method. This method requires that the test current is not less than 1A.The measured resistance value is small.High test currents are common: 1A, 3A, 10A, 20A, 40A, 50A, 100A, these are only used for single-phase measurements.
4. Contact resistance
Contact resistance is a parameter for the good connection of a conductive circuit.The unit of measurement is μΩ.Each type of high voltage circuit breaker is assigned a range of values.If the loop resistance exceeds the specified value, the conductive circuit may be poorly connected.In the case of high-current operation, the local temperature rise will increase when the contact fault occurs, and even a vicious cycle will lead to oxidation and burnout. Therefore, the circuit breaker used for high-current operation should pay more attention.
边栏推荐
猜你喜欢
随机推荐
Unity Obi插件修改到支持URP
Jmeter性能测试步骤入门
大文件上传和下载场景,如何节省成本?
极限挑战,如何做到分钟级搭建环境?
从软件哲学角度谈 Amazon SageMaker(第一讲)
运维--常用中间件
OpenSSF的开源软件风险评估工具:Scorecards
暴雨天,看天翼云如何“快准稳”防涝
【LeetCode】1413. 逐步求和得到正数的最小值
道路标识信息 (RSI)
MySQl表的增删查改(聚合查询+联合查询)
Mongodb增加权限管理
C语言程序设计笔记(浙大翁恺版) 第三周:判断
shell------常用小工具,sort,uniq,tr,cut
Computational Imaging Technology
实践数据湖iceberg 第三十九课 清理快照前后数据文件变化分析
网站授权QQ登录
优化软件测试成本的 7 个步骤
table中 You may have an infinite update loop in a component render function问题解决
C语言程序设计笔记(浙大翁恺版) 第六周:数据类型